Alerts - Defect Retest - Global Alert :
qa
Alerts severity - Success :
Test 124
Test upcoming outage alert :
Our interactive Outage Map helps you quickly determine if your service address is affected by an outage, including when an outage is scheduled to start or estimated to end.You can also sign up to receive alerts, get tips that help you and your family stay safe during an outage, and quickly connect to important resources and support programs should you require additional assistance during an outage emergency.
ST Broken Link 005 :
Test Broken Links - 2 in sce.com website 5Test Broken Links - 2 in sce.com website - 119Test Broken Links - 2 in sce.com website - 120

Regulatory Information - SCE Load Profiles

2012 Static Load Profiles

The data files in this section are static load profiles for 2012. Each file is a rate group annual profile developed using a three-year average of historical rate group load profiles. Static Load Profiles are produced for 11 separate groups in advance of the target year and use the previous three years with complete data. The last class average load profile used is a two-year lag of the target year. Refer to the methodology of creating static load profiles for a description of the estimation process.

On May 18, 1998, SCE began implementing dynamic load profiles in place of static profiles for residential (Domestic Single/Multiple), Small Commercial (GS-1), and medium commercial/industrial (GS-2) customers. As of that date, only dynamic profiles should be used for billing or settlement for these three rate groups.

All SCE rate group load profiles are reported in Pacific Standard Time (PST), with hourly values recorded in kW.

2012 Static Load Profiles
Customer Class (Rate Group) Load Profile Id (text Files) Description Rate Schedules
Domestic DOM-S/M Domestic Single/Multiple DOMESTIC, D-CARE, D-CARE-APS, D-CARE-APS-E, DE, DE-APS, DE-APS-E, DE-FERA, DE-S, DE-FERA-APS, DE-FERA-APSE, DE-TOU-1, DE-TOU-2, D-APS, D-APS-E, D-FERA, D-FERA-APS, D-FERA-APS-E, D-PG-S, D-S, D-S-CARE, D-S-FERA, TOU-D-1, TOU-D-1-CARE, TOU-D-2, TOU-D-2-APS, TOU-D-2-CARE, TOU-D-T, TOU-D-T-APS, TOU-D-T-APSE, TOU-D-T-C-AE, TOU-D-T-CARE, TOU-D1-APS-E, TOU-D1-C-AE, TOU-D1-C-APS, TOU-D2-APS-E, TOU-D2-C-AE, TOU-D2-C-APS, TOU-DE-1-AE, TOU-DE-1-APS, TOU-DE-2-AE, TOU-DE-2-APS, TOU-DE-T, TOU-EV-1
Domestic DOM-MM Master-Metered DM, DM-CARE, DMS-1, DMS-2, DMS-3
LSMP GS-1 General Service, Non-demand Metered, Small Commercial GS-1, GS-1-APS, GS-1-APS-C, GS1-APS-E, GS-1-APS-E-C, GS-1-CARE, GS-1-CIF, GS-1-G-S, GS-1-SCE, TOU-EV-3, TOU-GS-1, TOU-GS-1-AE, TOU-GS-1-APS
LSMP TC-1 Traffic Control TC-1
LSMP GS-2 General Service, Demand Metered, Medium Commercial/Industrial GS-2, GS-2-A-C/GS1, GS-2-A/GS1, GS-2-AE/GS1, GS-2-AEC/GS1 GS-2-APS, GS-2-APS-C, GS-2-APS-E, GS2-APS-E-C, GS-2-C/GS1, GS-2-CARE, GS-2-S, GS-2-S/GS1, GS-2-SCE, GS-2/GS1, GS2T-A, GS2T-A-APS, GS2T-A-APS-E, GS2T-B, GS2T-B-APS, GS2T-B-APS-E, GS2T-B-EDW, GS2T-B-S, GS2T-B/GS1, GS2T-R, GS2TA/GS1, GS2TB-AE/GS1, SEQUOIA, TOU-EV-4
LSMP TOU-GS General Service, Time-of-Use, Medium Commercial/Industrial TGS3-C-CPP, TGS3-CPP. TOU-GS3-A, TOU-GS3-A-S, TOU-GS3-AAES, TOU-GS3-B, TOU-GS3-B-C, TOU-GS3-B-S, TOU-GS3-BAES, TOU-GS3-R, TOU-GS3-SOP, TOU-GS3A-AE, TOU-GS3A-APS, TOU-GS3B-AE, TOU-GS3B-APS, TOU-GS3B-EDW
AG&P PA-1 Small Agriculture & Pumping PA-1, PA-1-I, PA-1-SCE
AG&P PA-2 Agriculture & Pumping, Demand Metered PA-2, PA-2-I, PA-2-S, PA-2-SCE
AG&P TOU-PA-5 Agriculture & Pumping, Time-of-Use TOU-PA-5, TOU-PA-5-I, TOU-PA-5-S
AG&P Ag-TOU Agriculture & Pumping,Time-of-Use TOU-P-S-1-AP, TOU-P-S-2-AP, TOU-PA-A, TOU-PA-B , TOU-PA-B-I, TOU-PA-B-S, TOU-PA-ICE, TOU-PA-ICE-I, TOU-PA-SOP-1, TOU-PA-SOP-2
NOTE: RATE SCHEDULE AND VOLTAGE (KV) LEVEL DETERMINE LARGE POWER LOAD PROFILE ID.
Large Power TOU8-SEC General Service, Time-of-Use,Large Power(>500 kW), Secondary Voltage (Below 2 kv) RTP-2, RTP-2-S, RTP-2-SGDR-T, TOU-8, TOU-8-B, TOU-8-B-AE-S, TOU-8-B-APS, TOU-8-B-APSE, TOU-8-B-S, TOU-8-CPP, TOU-8-R, TOU-8-S
Large Power TOU8-PRI General Service, Time-of-Use,Large Power (>500 kW), Primary Voltage (2 kv - 50 kv) RTP-2, RTP-2-S, RTP-2-SGDR-T, TOU-8, TOU-8-B, TOU-8-B-AE-S, TOU-8-B-APS, TOU-8-B-APSE, TOU-8-B-S, TOU-8-CPP, TOU-8-EDW, TOU-8-R, TOU-8-S
Large Power TOU8-SUB General Service, Time-of-Use,Large Power (>500 kW), Sub-Transmission Voltage (Above 50 kv) RTP-2, RTP-2-S, RTP-2-SGDR-T, TOU-8, TOU-8-B, TOU-8-B-AE-S, TOU-8-B-APS, TOU-8-B-APSE, TOU-8-B-S, TOU-8-CPP, TOU-8-EDW, TOU-8-R, TOU-8-S, MARCH-AFB
Street Lighting St-Ltng Street and Area Lighting AL-2-A, AL-2-B, DWL-A, DWL-B, DWL-C, LS-1, LS-2, LS-2-4, LS-2- B, LS-3, OL-1, OL-1-ALLNITE, LS-1-ALLNITE, LS-1-MIDNITE, LS-1-TAP

If you have any questions regarding SCE load profiling, please contact Cyrus Sorooshian at SCE.

Expose as Block
No